Atmospheric water generator calculator

An atmospheric water generator (AWG) cools air below its dew point so vapor condenses into water. How much it makes depends on how much water is in your air. Check that here before you trust a rated output.

1. Your air
2. Your machine (optional, from its spec sheet)
Your results
Dew point
64.9 °F
The coil must be colder than this before any water condenses
Water in the air
15.1 g/m³
Grams of water vapor in each cubic meter of air
Most a coil at 40 °F can pull out
8.6 g/m³
About 116 cubic meters of air per liter of water
Your machine
–
Add the airflow or the rated output and rating conditions

The math: saturation vapor pressure uses the Magnus formula, es = 6.1094 × exp(17.625 T ÷ (T + 243.04)) hPa, with T in °C. Absolute humidity = 216.7 × vapor pressure ÷ (T + 273.15). Water a coil can remove = the air's absolute humidity minus the saturated absolute humidity at the coil temperature. The ceiling assumes every cubic meter of air is cooled all the way to the coil temperature, which no real machine does. The scaled estimate assumes output rises and falls in step with removable water, which is only a rough guide.

How to read the results

For your local humidity, use the average relative humidity and temperature for your area and season from a nearby weather station. Humidity changes through the day, so a machine running on cool, humid nights may do better than the daily average suggests.

AWGs use electricity to run the compressor and fans. Check the watts on the spec sheet and add them to the solar sizing calculator. For other water sources, see the rainwater calculator and the Water hub.